Safety and Electromagnetic Field Guidelines
Local absorbed power density (>6 GHz to 300 GHz): For local exposure for both the Head and Torso
and Limb regions (6 GHz to 300 GHz), an absorbed power density (Sab) limit averaged over 6 minutes
and a square 4 cm2 surface area of the body was set for the local temperature rise of 5°C or 2°C depend
ing on tissue type in Table 7.5. Furthermore, to account for focal beam exposure from 30 to 300 GHz, the
absorbed power density averaged over a square 1 cm2 surface area of the body must not exceed two times
that of the 4 cm2 basic restrictions for workers or the general public.
Local absorbed energy density (>6 GHz to 300 GHz): In addition, for frequencies from 6 to 300 GHz,
ICNIRP sets an additional limit expressed as local absorbed energy density (Uab) for exposure intervals
of <6 minutes, as a function of time, to ensure that the cumulative energy permitted by the 6-minute
average absorbed power density basic restriction is not absorbed by tissues too rapidly in Table 7.6.
In ICNIRP 2020, the basic restrictions of SAR remain unchanged; the basic restriction, which was
expressed in terms of spatial power density at 10–300 GHz, is now expressed in terms of Sab, the locally
absorbed power density absorbed by tissues near the body surface. Basic restriction for local exposure is
now expressed in terms of local SAR for the frequency range of 100 kHz to 6 GHz and local Sab for the
frequency range of 6–300 GHz. On the other hand, the basic restrictions for induced electric feld into
the body from 100 kHz to 10 MHz are the same as in ICNIRP 2010.
7.8.1.2 Reference Level
In ICNIRP 2020, reference levels are presented in terms of electric feld strength (V/m), magnetic feld
strength (A/m), power density (W/m2), and induced current (mA) to the extremities, in the frequency
range from 100 kHz to 300 GHz. Reference levels shown in Tables 7.7–7.9 have been derived from the
basic restrictions by a combination of computational and measurement studies for worst-case exposure
scenarios.
TABLE 7.7 Reference Levels in ICNIRP Guidelines for Exposure, Averaged over 30 Minutes and the Whole Body,
to Electromagnetic Fields from 100 kHz to 300 GHz (Unperturbed rms Values)
Exposure
Scenario
Frequency Range
Incident E-Field
Strength; Einc (V/m)
Incident H-Field
Strength; Hinc (A/m)
Incident Power
Density; Sinc (W/m2)
Occupational
0.1–30 MHz
>30–400 MHz
0.7
660/fM
61
4.9/fM
0.16
NA
10
>400–2000 MHz
>2–300 GHz
0.5
3fM
NA
0.5
0.008fM
NA
fM/40
50
General
public
0.1–30 MHz
>30–400 MHz
>400–2,000 MHz
>2–300 GHz
0.7
300/fM
27.7
0.5
1.375fM
NA
2.2/fM
0.073
0.5
0.0037fM
NA
NA
2
fM/200
10
Source: Reproduced from ICNIRP, Health Physics 118:483–524, 2020.
Notes:
1. “NA” signifes “not applicable” and does not need to be taken into account when determining compliance.
2. fM is frequency in MHz.
3. Sinc, Einc, and Hinc are to be averaged over 30 minutes, over the whole-body space. Temporal and spatial averaging of each
of Einc and Hinc must be conducted by averaging over the relevant square values.
4. For frequencies of 100 kHz to 30 MHz, regardless of the far-feld/near-feld zone distinctions, compliance is demonstrated
if neither Einc or Hinc exceeds the above reference level values.
5. For frequencies of >30 MHz to 2 GHz: (a) within the far-feld zone: compliance is demonstrated if either Sinc, Einc or Hinc,
does not exceed the above reference level values (only one is required); Seq may be substituted for Sinc; (b) within the radia
tive near-feld zone, compliance is demonstrated if either Sinc, or both Einc and Hinc, does not exceed the above reference
level values; and (c) within the reactive near-feld zone: compliance is demonstrated if both Einc and Hinc do not exceed the
above reference level values; Sinc cannot be used to demonstrate compliance, and so basic restrictions must be assessed.
6. For frequencies of >2 GHz to 300 GHz: (a) within the far-feld zone: compliance is demonstrated if Sinc does not exceed
the reference level values; Seq may be substituted for Sinc; (b) within the radiative near-feld zone, compliance is demon
strated if Sinc does not exceed the above reference level values; and (c) within the reactive near-feld zone, reference levels
cannot be used to determine compliance, and so basic restrictions must be assessed.